PRODUCTEN


KetaSpire® KT-880 BK 95: Medical Polyether Ether Ketone PEEK
Productconstructie
What is KetaSpire® KT-880
KetaSpire® KT-880 BK 95 is a member of Solvay's high-performance Polyether Ether Ketone PEEK family. While maintaining the inherent high-temperature and chemical stability of PEEK resin, this material further enhances flame retardancy, processing flow, and medical-grade biocompatibility.
Its performance covers a wide range of applications, from film and extrusion grades to medical and drinking water contact grades, providing greater design flexibility for precision components in demanding environments.
I. Key Highlights
Uitstekende vlamvertraging: UL94 V-0 (3.0mm) is compliant, making it suitable for electrical and medical devices with stringent safety standards.
High-temperature long-term stability: RTI (Electrical/Structural) ratings are both 260°C, enabling long-term operation under high thermal and electrical stresses.
Multiple sterilization compatibility: Supports steam, autoclave, gamma irradiation, ethylene oxide, and electron beam sterilization.
Excellent dimensional stability and fatigue resistance: Ensures controlled deformation under long-term loads in medical devices and aerospace connectors. High Flow: MFR (400°C, 2.16kg) is 36 g/10min, significantly improving the efficiency of injection molding and thin-walled product processing.
II. Performance Analysis
UL | Voorwaarde | Standaard | Waarde | Eenheid | |||
CTI | EN 60112 | 4 | BV | ||||
GWFI | 0.85mm | EN 60695-2-12 | 960 | °C | |||
GWFI | 1,5 mm | EN 60695-2-12 | 960 | °C | |||
GWIT | 3,0 mm | EN 60695-2-13 | 850 | °C | |||
HAI | NC BK 0.2mm | UL746A | 1 | BV | |||
HAI | NC BK 1,5 mm | UL746A | 1 | BV | |||
HAI | NC BK 3,0 mm | UL746A | 1 | BV | |||
HVTR | UL746A | 3 | BV | ||||
HWI | NC BK 0.2mm | UL746A | 3 | BV | |||
HWI | NC BK 1,5 mm | UL746A | 1 | BV | |||
HWI | NC BK 3,0 mm | UL746A | 1 | BV | |||
RTI | Elec NC BK 0.2mm | UL 746B | 260 | °C | |||
RTI | Elec NC BK 0.75mm | UL 746B | 260 | °C | |||
RTI | Imp NC BK 0.85mm | UL 746B | 180 | °C | |||
RTI | Imp NC BK 1.5mm | UL 746B | 180 | °C | |||
RTI | Str NC BK 1.5mm | UL 746B | 260 | °C | |||
RTI | Str NC BK 3.0mm | UL 746B | 260 | °C | |||
Boogweerstand | ASTM D495 | 6 | BV | ||||
Vlamclassificatie | NC BK 0.2mm | UL94 | HB | ||||
Vlamclassificatie | NC BK 1,5 mm | UL94 | HB | ||||
Vlamclassificatie | NC BK 3,0 mm | UL94 | V-0 | ||||
Mechanisch gedrag | Voorwaarde | Standaard | Waarde | Eenheid | |||
Verlenging | Opbrengst | ISO527 | 5.0 | % | |||
Verlenging | Opbrengst 50mm/min | ASTM D638 | 5.2 | % | |||
Verlenging | Pauze | ISO527 | 10~20 | % | |||
Verlenging | Breuk 50mm/min | ASTM D638 | 10~20 | % | |||
Schuifsterkte | ASTM D732 | 95.1 | MPa | ||||
Druksterkte | ASTM D695 | 123 | MPa | ||||
Buigsterkte | ASTM D790 | 153 | MPa | ||||
Buigmodulus | ISO178 | 3900 | MPa | ||||
Izod Un-inkeping Impact | ASTM D4812 | Let op | |||||
Izod Un-inkeping Impact | ISO180 | Let op | |||||
Treksterkte | 50 mm/minuut | ASTM D638 | 100 | MPa | |||
Treksterkte | Opbrengst | ISO527 | 102 | MPa | |||
Trekmodulus | 1,0 mm/min | ASTM D638 | 3700 | MPa | |||
Poisson's Ratio | ASTM E132 | 0.37 | |||||
Thermisch | Voorwaarde | Standaard | Waarde | Eenheid | |||
Warmtegeleidingscoëfficiënt | ASTM E1530 | 0.25 | W/(m·K) | ||||
Soortelijke warmte | 50°C | ASTM C351 | 1330 | J/(kg·°C) | |||
Soortelijke warmte | 200°C | ASTM C351 | 1930 | J/(kg·°C) | |||
HDT | Gegloeid 1,8 MPa | ASTM D648 | 160 | °C | |||
Smelttemperatuur | ASTM D3418 | 343 | °C | ||||
Glasovergangstemperatuur | ASTM D3418 | 147 | °C | ||||
CLE | Flow -50.0~50°C | ASTM E831 | 5E-5 | cm/cm/°C | |||
Fysieke eigendom | Voorwaarde | Standaard | Waarde | Eenheid | |||
Wateropname | 24 uur | ASTM D570 | 0.10 | % | |||
Krimp | Stroom | ASTM D955 | 1.4~1.6 | % | |||
Krimp | xFlow | ASTM D955 | 1.5~1.7 | % | |||
Dikte | ASTM D792 | 1.30 | g/cm³ | ||||
Smeltviscositeit | 400°C 1000sˉ1 | ASTM D3835 | 150 | Pas | |||
Smeltindex | 400°C 2.16kg | ASTM D1238 | 36 | g/10min | |||
Elektrische eigenschappen | Voorwaarde | Standaard | Waarde | Eenheid | |||
Diëlektrische constante | 1KHz | ASTM D150 | 3.01 | ||||
Volumeweerstand | ASTM D257 | 3.8E+17 | Ω.cm | ||||
Diëlektrische sterkte | 3,0 mm | ASTM D149 | 15 | kv/mm | |||
Dissipatiefactor | 1KHz | ASTM D150 | 0.001 | ||||
Oppervlakteweerstand | ASTM D257 | 1.9E+17 | Ω | ||||
Hardheid | Voorwaarde | Standaard | Waarde | Eenheid | |||
Rockwell-hardheid | M(Schaal) | ASTM D785 | 102 | ||||
Ontvlambaarheid | Voorwaarde | Standaard | Waarde | Eenheid | |||
Vlamclassificatie | NC BK 0.2mm | UL94 | HB | ||||
Vlamclassificatie | NC BK 0.75mm | UL94 | HB | ||||
Vlamclassificatie | NC BK 3,0 mm | UL94 | V-0 |
Robust Mechanical Properties
Tensile strength of approximately 100 MPa and flexural strength of approximately 150 MPa, demonstrating a combination of rigidity and toughness. The material exhibits stable performance in impact and fatigue tests, making it suitable for components subjected to long-term mechanical loads.
Excellent Thermal Stability
With a high melting point of 343°C and a heat deflection temperature of approximately 160°C, it maintains structural integrity under high temperatures and repeated thermal cycling.
Uitstekende elektrische isolatie
Volume resistivity of approximately 3.8 × 10¹⁷ Ω·cm and dielectric strength of 15 kV/mm, it is suitable for high-voltage insulation and electronic connection systems.
Flame retardancy and strong safety
UL94 V-0 rating (3 mm), GWFI and GWIT ratings of 960°C and 850°C, respectively, demonstrate excellent flame retardancy and arc protection.
Chemical resistance and wide compatibility with sterilization
It offers stable resistance to acids, alkalis, oils, and a variety of chemical media. It is compatible with various sterilization methods, including steam, high pressure, ethylene oxide, and radiation, making it suitable for the repeated use of medical devices and industrial parts.
Iii. Process Compatibility
KetaSpire® KT-880 BK 95 has excellent processing flexibility and can be applied to various forming methods:
・Injection molding: Its melt has a relatively high fluidity (about 150 Pa·s), which can shorten the molding cycle while maintaining the precision of the product.
・Extrusion and blow molding: Suitable for the production of films, profiles and hollow products, ensuring uniform product structure.
・Thermoforming and CNC machining: It features excellent dimensional stability and can meet the secondary processing requirements of high-precision components.
In the manufacturing of medical equipment and aviation structural components, this material has good interface compatibility with metal substrates such as stainless steel and titanium alloy, supporting the integrated forming and assembly of composite parts.
Iv. Typical Application Fields
Industry | Representative Applications | Material Advantages |
Aerospace | Cable connectors, fuel system components | Flame retardant, lightweight, high temperature resistance |
Medical Devices | Surgical instruments, dental components, sterilizable housings | Repeated sterilization capability, biocompatibility |
Electrical & Electronics | Insulating brackets, sensor housings | High dielectric strength, thermal stability |
Oil & Gas | Pump seals, valve assemblies | Chemical resistance, fatigue resistance |
Industrial Equipment | Precision films, bearing housings | Wear resistance, low water absorption |
V. Industry Trends and Competitive Advantages
In medical and aerospace manufacturing, polyetheretherketone (PEEK) is replacing traditional metals and engineering plastics such as PPS and PEI, becoming the mainstream choice for high-end parts.
The high flowability and multi-standard certifications of KetaSpire® KT-880 BK 95 make it suitable not only for mass injection molding but also for the production of precision films and high-purity components.
It reduces molding costs without sacrificing strength, helping manufacturers achieve a balance between high performance and manufacturability.
VI. Recommended Materials Similar to KetaSpire® KT-880
Productmodel | Dikte | Treksterkte | Verlenging | Krimp | Trekmodulus | Warmteafbuigingstemp. | Izod Impact (Notched) | Buigmodulus | Izod Impact (Unnotched) | Buigsterkte | Buigsterkte |
KT-880 BK 95 | 1.30 g/cm³ | 100 MPa | 5.00% | 1.4~1.6 % | 4000 MPa | 160 °C | 5.40 kJ/m² | 3800 MPa | — | 153 MPa | 153 MPa |
KT-880 BK | 1.3 g/cm³ | 102 MPa | 5.20% | 1.50% | 3700 MPa | 160 °C | 53 J/m | 3800 MPa | — | 153 MPa | 153 MPa |
KT-880 CF30 | 1.41 g/cm³ | 218 MPa | 1.70% | 0.0~0.20 % | 20900 MPa | 315 °C | 64 J/m | 17900 MPa | 640 J/m | 321 MPa | 321 MPa |
KT-880 GF30 BG 20 | 1.53 g/cm³ | 162 MPa | 3.10% | 0.1~0.3 % | 11200 MPa | 315 °C | 7.04 kJ/m² | 10500 MPa | 86.73 kJ/m² | 260 MPa | 260 MPa |
KT-880 FW30 | 1.45 g/cm³ | 180 MPa | 1.80% | 0.55% | 13500 MPa | — | 68 J/m | 13500 MPa | 530 J/m | 280 MPa | 280 MPa |
KT-880 NT | 1.3 g/cm³ | 100 MPa | 5.20% | 1.40~1.60 % | 3700 MPa | 160 °C | 53 J/m | 3800 MPa | — | 153 MPa | 153 MPa |
KT-880 GF20 | 1.46 g/cm³ | 152 MPa | 3.70% | — | 8200 MPa | — | 60 J/m | 7860 MPa | 770 J/m | 254 MPa | 254 MPa |
KT-880 GF30 BK 95 | 1.53 g/cm³ | 162 MPa | 3.10% | 0.1~0.3 % | 11200 MPa | 315 °C | 7.04 kJ/m² | 10500 MPa | 86.73 kJ/m² | 260 MPa | 260 MPa |
KT-880 SL30 | 1.48 g/cm³ | 162 MPa | 1.90% | 0.65~0.85 % | 14500 MPa | 293 °C | 5.83 kJ/m² | 11700 MPa | 32.1 kJ/m² | 225 MPa | 225 MPa |
KT-880 CF40 | 1.46 g/cm³ | 258 MPa | 1.60% | — | 33000 MPa | 332 °C | 80 J/m | 30000 MPa | 750 J/m | 386 MPa | 386 MPa |
KT-880 NL | 1.30 g/cm³ | 100 MPa | 5.20% | 1.70% | 3700 MPa | 160 °C | 53 J/m | 3800 MPa | — | 153 MPa | 153 MPa |
KT-880 GF15 NT | 1.42 g/cm³ | 138 MPa | 5.00% | — | 6610 MPa | 278 °C | 4.79 kJ/m² | — | 67.34 kJ/m² | 231 MPa | 231 MPa |
KT-880 CF 30 MR | 1.41 g/cm³ | 218 MPa | 1.70% | 0.10% | 20900 MPa | 315 °C | 64 J/m | 17900 MPa | 640 J/m | 321 MPa | 321 MPa |
VII. FAQ: Frequently Asked Questions Before Purchasing
Q1: What is the difference between KetaSpire® KT-880 BK 95 and standard PEEK?
A: This model is flame-retardant and medical-grade, offering enhanced sterilization compatibility and electrical safety, making it suitable for demanding industries.
Q2: Can this material be used for food contact?
A: It is certified for drinking water contact, and some batches meet food-grade requirements. We recommend verifying the compliance certificate when purchasing.
Q3: Does Juyuan offer modification solutions?
A: Juyuan can provide glass fiber reinforced, lubricated, or conductive modified versions based on customer needs to suit different operating conditions.
VIII. Juyuan - Your PEEK Supply and Technology Partner
As a supplier specializing in the international trade of plastic raw materials for 24 years, Juyuan not only provides PEEK materials from original sources but also offers modification recommendations, molding guidance, and alternative options tailored to industry needs.
Whether you're in the medical device, aviation manufacturing, or petrochemical industries, Juyuan can match you with the most suitable polyether ether ketone PEEK solution.
【Gerelateerde aanbevelingen】
InLube™ PEEKBGHF: Lubricated PEEK Polyether Ether Ketone Meer informatie>
LUVOCOM® 3F PEEK CF 9676 BK: Chemical-Resistant PEEK Polymers Meer informatie>
Glove Materials: PVC, NBR, and TPE Cost Comparison Meer informatie>